• NOVX 3352/3362 Voltage detection

    NOVX 3352/3362 Voltage detection


    Simco-Ion’s Novx brand of Passive (Model 3352) and Active (Model 3362) Multi-fan Closed-loop Ionizer Controllers provide the capability to simultaneously detect, measure, record and monitor electrostatic voltages in multiple locations. The versatile antennas used with these systems allow their use in a variety of applications including monitoring sensitive workstations, in-tool voltages, or ionizer performance with the option of closed-loop control to select ionizer products. Up to 3 sensors can be connected to an individual instrument. This multi-channel capability provides a cost-effective monitoring solution for multiple areas or ionizers. Data input is actively monitored and logged with time stamps using Calibrator_Reader. The instruments have user settable thresholds and alarm levels that provide a proactive safeguard for critical areas when interfaced to an alarm output. Out of range conditions can trigger a remote alarm light or audible alarms, shut down a critical process, or make adjustments to an ionizing fan.


    • Features and Advantages
    • Specifications
    • Applications

    Features


    ○ Digital, microprocessor-based controllers, multi-channel, digital I/O, auxiliary I/O, local addressability, RS-485/Modbus or Ethernet data output

    ○ Passive (unpowered) and active antenna configurations

    ○ Precision resolution

    ○ Programmable closed-loop control for up to 3 SSDC ionizer fans or a 3-fan blower

    ○ Programmable alarm set-points with tool shutdown option

    ○ Voltage/polarity displays, local red/green LEDs each channel

    Model 3352 Model 3362
    Input Voltage 24 VDC 24 VDC
    Capacity 1,2 or 3 fans 1,2 or 3 fans
    Reporting Range 0 to ±5000V 0 to ±150V
    Accuracy 1V for <20V; ±5% for >20V 1V for <20V; ±5% for >20V
    Audible Alarm Set-points ±0.5V (min) ±1V (min)
    LEDs/Channel Red/green or alarm indicator Red/green or alarm indicator
    Alarm Set-point Programmable Programmable
    Zero Set-point Programmable Programmable
    Aux Out Open collector Open collector
    Output Signals Digital Digital
    Antennas up to 3 channels up to 3 channels
    Decay Testing NA up to 3 channels
    Communication Novx Comm,RS-485/Modbus,Ethernet Novx Comm,RS-485/Modbus,Ethernet
    Digital Display/Channel 4-Digit 4-Digit
    Dimensions 5.1W x 17.3D x 16.5H cm 5.1W x 17.3D x 16.5H cm
    Weight 0.95 kg 1 kg
    Enclosure Stainless Steel Stainless Steel
    Warranty Two-year limited warranty Two-year limited warranty
    Certifications
    Power Adapter 14-21327
    Input Voltage 100-240 VAC 50/60 Hz
    Output Voltage 24 VDC,30W
    Dimensions 10.3H x 4.2W x 2.9D cm
    Weight 140g
    Certifications     

    ◆ APPLICATIONS:


    • It can detect static voltage after located sensors into sensitive area .NOVX system could record data and Alarm, Novx could upload all data to PC when connected by cable. And loop-control ionizers