• Picarro/ AMC Analyzer SI 2000

    Picarro/ AMC Analyzer SI 2000


    Applications requiring trace gas analysis include environmental monitoring, emissions monitoring, greener automotive engine development, semiconductor fabs, cleanroom technology and bio-pharmaceutical process monitoring. All these applications can benefit from a turnkey analyzer that provides real-time speed, high precision and sensitivity to parts per billion and beyond. And, from a practical standpoint, the ideal trace gas analyzer requires minimal or no sample preparation or dilution, and is contained in a rugged, compact platform with low operating costs. Specifically, the latter means no need for a trained technician and, optimally, the capability for remote, unmanned operation.
    CRDS is the first trace-gas analysis instrumentation to meet all these needs, and it can even provide isotope ratios for environmental and biomedical applications. Just as important, the same Picarro CRDS analyzers can be used as unmanned remote monitors, industrial process sensors, and reference laboratory instruments, greatly simplifying transfer of standards and protocols. And the extraordinary low drift of these instruments means they can operate for months without recalibration in most applications.

    • Features and Advantages
    • Specifications
    • Applications

    ◆ Characteristic


    ○ Superb sensitivity, precision & accuracy with virtually no drift

    ○ Fast, continuous, real-time measurements without interference

    ○ Large dynamic range with high linearity

    ○ Large dynamic range with high linearity

    ○ Installed and operational in minutes

    ○ Rugged and insensitive to changes in ambient temperature, pressure or vibration

    ○ 1 year warranty


    ◆ Advantage


    ○ Response time (seconds instead of minutes)

    ○ Accuracy, Precision and LDL at PPT levels.

    ○ Stability : no calibration

    ○ Maintenance cycle: ( 6month,1year)

    ○ Preventative Maintenance @ very low price

    Performance
    Specifications

    SI2104

     SI2108

    SI2306

    H2S

    HCI

    H2O

    HF
     (SI2205 for HF only)

    NH3
    (SI2103 for NH3 only)

    Precision

    1.5 ppb (10 sec),  
    0.5 ppb (100 sec)

    45 ppt (10 sec),
    15 ppt (100 sec)

    20 ppm + (8 x %H2O) (10 sec)
    10 ppm + (4 x %H2O) (100 sec)

    30 ppt (10 sec),
    10 ppt (100 sec)

    300 ppt (10 sec),
    100 ppt (100 sec)

    Lower Detectable Limit
     (100 sec., 3
    σ)

    1 ppb

    45 ppt

    30 ppm

    30 ppt

    300 ppt

    Method Detection Limit
    (per Semi C10-1109)

    3 ppb

    250 ppt

    40 ppm

    500 ppt

    500 ppt

    Linearity
    (per IEC 61207)

    ±1%

    ±1%

    ±1%

    ±1%

    ±1%

    Accuracy at span

    ±5% @ full scale

    ±5% @ full scale

    ±5% @ full scale

    ±5% @ full scale

    ±5% @ full scale

    Accuracy at zero

    ±2 ppb

    ±50 ppt

    ±40 ppm

    ±25 ppt

    ±100 ppt

    Instrument-to-Instrument
    Consistency

    ±5% @ full scale
    ±2 ppb @ zero

    ±5% @ full scale
    ±50 ppt @ zero

    ±5% @ full scale
    ±40 ppm @ zero

    ±5% @ full scale
    ±25 ppt @ zero

    ±5% @ full scale
    ±100 ppt @ zero

    Measurement Range

    010 ppm

    02 ppm

    040000 ppm

    01 ppm

    010 ppm

    Measurement Interval*

    <4 seconds

    <3 seconds

    <4 seconds

    Sample Flow Rate

    ~0.4 slm

    ~2 slm

    ~2 slm

    Combined Response Times
     (T90/10 + T10/90) @ 20 ppb

    <20 sec (100 ppb challenge)

    <3 min

    <20 sec (10,000 ppm challenge)

    <3 min

    Fall Times T90/10 @ 20 ppb

    <10 sec (100 ppb challenge)

    <1 min

    <10 sec (10,000 ppm challenge)

    <1 min


    SI2000 Series System Specifications

    Measurement Technique

    Cavity Ring-Down Spectroscopy

    Calibration Period Recommendation

     Calibration not required - Initial validation at 6 months, then every 12 months thereafter

    Time Required to Perform Validation

    Estimated at <15 minutes per manufacturers instructions

    Measurement Cell Temperature Control

    ±0.005°C

    Measurement Cell Pressure Control

    ±0.0002 atm

    Operating Temperature

    15 to 35°C (operating); -10 to 50°C (storage)

    Ambient Humidity

     <99% RH non-condensing

    Accessories

     Pump (external, included), keyboard (included), mouse (included), LCD monitor (optional), Maintenance Kit (optional)

    Communication Interfaces

     RS-232, Ethernet, USB, analog 010 V, Modbus, 4-20mA(optional)

    Fittings

     14 Swagelok® PFA Fittings

    Dimensions

     Analyzer: 17 w × 8.38 h x 24.4 d (43.2 × 21.3 × 62 cm)

    Weight

     73 lbs. (33.18 kg) including external pump

    Power Requirements

     100240 VAC, 4763 Hz (auto-sensing), <400 W (total): 250 W (analyzer), 150 W (pump) at steady state

    Warranty

    12 Months

    Certifications

    CE Mark

    Country of Manufacture

    USA

    ◆ Applications



    • wafer fab manufacturing (Advanced Technologies)
    • Equipment Monitoring
    • FOUP Monitoring
    • OEM Manufacturer