SUTO's S 505 incorporates next-generation measurement techniques and state-of-the-art user interface design.Experienced users know that dew point measurements need to measure online pressure as dew point is related to pressure (see ISO 8573).S 505 measures both dew point and pressure at the same time, so users can fully trust the accuracy of the measured data and avoid human error.S 505 includes two sensors: sensor Q uses the new QCM technology, which can provide rapid and accurate measurements in tiny amounts of moisture gas below -30 ºC to -100 ºC.Sensor P is suitable for high moisture applications, from -50℃ to +50℃, using a SUTO polymer sensor more suitable for this range.These two sensors can be easily replaced.
○ Measuring dew point, temperature and pressure (three in one)
○ Three measurement ranges can be selected:
Q: -100 ... -30 ºC Applicable to the application of trace moisture
P: -50 ... +50 ºC Standards application
Q+P: Cover the entire measuring range of the dew point meter
○ Fashionable and advanced color touch screen
○ Data recorder,USB interface and bluetooth connected to portable printer
○ The measurement/standby measuring room responds quickly
○ Including application software
○ Fashionable and advanced, easy to operate color touch screen user interface, similar to a smartphone
○ The data logger can record more than 100 million values on the flash memory card.The flash memory card can be removed from the host, and the recording information can be quickly transferred to personal power, or transferred or read through USB and bluetooth.
○ Portable printers can be used to print measurements, locations and date.Of course these measurements can be kept in your office at the same time for making reports in your office.
○ The S 505 kit contains a sturdy and durable suitcase, including a measuring chamber, battery charger,USB cable and a teflon hose used to quickly connect the compressed air system for rapid measurements.
S 505 | |
---|---|
Measure range(Sensor Q) | -100℃~-30℃ |
Measure range(Sensor P) | -50℃~+50℃ |
Measure range(Pressure) |
-0.1~1.5MPa |
Measure range(Temperature) | -30℃~+50℃ |
Accuracy(Dew point) | ±2℃ |
Accuracy(Pressure) | +0.005MPa |
Accuracy(Temperature*) | ±0.3℃ |
Measured gas | Non-corrosive gas |
Environment temprature | 0℃~+50℃ |
Transport temperature | -40℃~+65℃ |
Environment humidity | <90%,no-condensing |
EMC | IEC/EN 61326 |
Resonse time t90 | -50℃->-10℃:<10s,-10℃->-50℃:<5min |
USB charger | 5VDC,2A |
Power time |
6h |
Charging time |
4h |
Storage space | 4GB |
Storage media | SD card |